China      English

: 15053177366

Home/>Product>Breathing Apparatus

Electric supply long tube air respirator

Executive standard: GB6220-2009

  • Product model: Electric supply long tube air respirator
咨询电话:
15053177366
Product advantage

Executive standard: GB6220-2009
1 Product introduction

1.1 Overview

This instruction manual is mainly for the Haiante HAT-DS series powered supply long tube air respirator, systematically introduce its classification method, product features and how to use and maintain, to provide some guidance and help for the correct selection of respiratory protection products. Respiratory protective equipment is personal protective equipment. In production site, daily life and some extreme situations, respiratory protection products are used to avoid damage to the human body caused by toxic and harmful substances in the environment through the respiratory organs.
The powered supply air respiratory protection products rely on the power to overcome the resistance of the components, provide the air source, and ensure the normal breathing of the personnel, such as the Haiante electric supply long tube respirator. Its characteristic is that the motor power is overcoming the suction resistance, thereby reducing the user's physical load. It is suitable for use in environments and occasions where the work intensity is high, the ambient air pressure is low (such as the plateau), the situation is critical, and the personnel are nervous. Haiante HAT-DS series power supply long tube air respirator is suitable for chemical, petroleum, pharmaceutical industry, gas plant, urban construction underground construction and other industries, maintenance of tower tanks, underground construction and other operating environments, can protect the work in anoxic environment. It can prevent inhalation of harmful substances such as harmful gases, dust, and smoke, and effectively offset the danger of oxygen deficiency. It is more advantageous to use in narrow spaces such as underground pipes or large tanks.

1.2 Product Classification

Product illustration
 
Name
 
Model
 
Number of users
 
Powered Supply Long Tube Air Respirator (One Person Type) HAT-DS1
 
One person
Powered Supply Long Tube Air Respirator (Two Person Type) HAT-DS2 Two person
Powered Supply Long Tube Air Respirator (Four Person Type) HAT-DS3 Four person
According to the needs of customers, the company can provide 5 people, 6 people, 8 people and other electric supply long tube respirator series products.
   
  

3 INSTRUCTIONS FOR USE

3.1 USE  ENVIRONMENT

Haiante HAT-DS series powered supply long tube air respirator blower is a special motor driven rotary socket jet. The main unit is a non-explosion-proof product. When working, the main unit should be placed in a normal air environment, and the air should meet the breathing standards. The air enters the annular passage with the change of the cross-sectional area from the suction port, and the air outlet is compressed and ejected, and enters the mask through the long pipe of the gas transmission to realize the long-tube air respirator of the constant-flow air supply. It can be used in harsh environments such as lack of oxygen or toxic gases, smoke, and dust.

3.2 HOW  TO   USE

1. After turning on the power, observe whether there is any abnormality in the operation, check whether the pipeline and the joint are leaking, and operate normally without any problems.
2. When wearing, first connect the long tube to the blower outlet hose (tightly), and the other end to the mask inlet (tightly) 0.6m away from the mask, and fix the hose on the belt, it is appropriate to not interfere with the free movement of the body. Then, open the fan and bring the cover to enter the work area. This model can be used by one or two people. When using one, remove the tee and tighten it.
Precautions:
1. The blower should be placed in a clean atmosphere and have special care by Designated person.
2. If there is a power outage or the machine is abnormal, immediately inform the staff to evacuate the site.

4 MAINTENANCE

After the powered supply type long tube respirator is used, the mask should be cleaned and disinfected. The outside of the long tube is cleaned and packed after drying. Make sure that the operating state is intact for future use. The whole machine should be stored in a dry, ventilated, non-corrosive atmosphere, and should be kept away from heat and direct sunlight, and oil is prohibited.
Technical parameters

2 Technical indicators

2.1 Product Structure

 
 
Accessories Structure diagram (taking the two-person type electric supply long tube respirator as an example)
Air supply host
Air supply long tube
Gas flow regulating valve
Breathing hose
Full face mask
Fixing strap

2.2 The main technical parameters of the whole machine

Wind pressure 1000Pa
Rated voltage 220V
Rated power 120W/180W
Air supply flow >500L/min
Oil mist penetration rate ≤ 0.0005%
Expiratory resistance ≤98Pa
Field of view ≥85%
Long tube size 10~50 meters
Number of users 1~6 people
Protection time unlimited

2.3 motor technical parameters

model HAT-DSJ HAT-DSJ
specification
Suitable
Suitable for 1-2 people Single tube length 10-50 meters
 
Suitable for more than 2 people Single tube length 10-50 meters
Air volume 12m3/h 18m3/h
Wind pressure 7.5kPa 9kPa
Vacuum degree -5kPa -6.5kPa
Use wind pressure <6kPa <7kPa
power supply 220V AC/50HZ 220V AC/50HZ
power 120w 180w
Rotating speed 2820r/min 2820r/min
capacitance 4uF 500V AC 4uF 500V AC
Current 0.9A 1.1A
Protection IP54 IP54
insulation Class B Class B
Gas supply method
 
Positive pressure constant flow gas supply Positive pressure constant flow gas supply
Air supply 30L/min~350L/min 30L/min~350L/min

2.4 long tube introduction

Material
 
Food grade rubber cloth hose (black standard) Plastic tube (yellow transparent)
specification
 
The standard pipe length defaults to 10m, other lengths need to be cut or linked; generally 5 meters per unit, can be cut or combined into any length according to customer needs, such as 5m, 10m, 15m, 20m, etc. The length of the pipe is not 5 meters, and can be customized as needed.
Executive standard GB6220-2009
Inner diameter size 25mm
Diameter size 30mm
Compressive force Longitudinal (cross-sectional direction) with a pressure of 55 kg, transverse (in the direction of the tube) tensile 100 kg
Tolerance temperature range Operating environment temperature -30°C to 60°C can be used, non-toxic and tasteless, long tube maximum temperature can be up to 120°C

Display photos

In the previous: Air supply long pipe respirator

The next article: No more

Related products